c
2020 Sun Hydraulics 1 of 2
MODEL
X2DD
Solenoid-operated, rapid advance and feed flow control assembly with reverse
flow check
CAPACITY: 120 L/min.
Meter in P Normally Open
This assembly consists of a fully-adjustable, pressure-compensated flow control with reverse-flow check which
provides precise flow regulation for meter-in or meter-out applications where there may be wide pressure
fluctuations. It is infinitely adjustable from nearly closed up to the maximum flow. An integral high-capacity check
valve provides unrestricted flow in the reverse direction. The rapid or feed rate is selected by a solenoid operated
(normally open or closed) 2-way, 2-position valve.
sunhydraulics.com/model/X2DD
TECHNICAL DATA
Body Type Sandwich
Interface ISO 05
Body Features Meter in P
Stack Height 62 mm
Seal Plate Included (see notes) No
NOTES
Seal retainer plate is not required for this assembly.
For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port
type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port
type/size specified.
c
2020 Sun Hydraulics 2 of 2
MODEL
X2DD
Solenoid-operated, rapid advance and feed flow control assembly with
reverse flow check
CAPACITY: 120 L/min.
Continued from
previous page
(F)
(L)CONTROL
L Standard Screw Adjustment
H Calibrated Handknob with Detent Lock
K Handknob
(A)ADJUSTMENT RANGE
A .2 - 12 gpm (0,8 - 45 L/min.)
B .2 - 3 gpm (0,8 - 11 L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
(224)COIL *
224 DIN 43650 4 pin (Hirschman) 24 VDC
No Coil
* Additional coil options are available
INCLUDED COMPONENTS
Part Description Quantity
500-001-014* O-Ring 5
DFDA8DN Cartridge 1
DTAFMHN224 Cartridge 1
FDCBLAN Cartridge - Primary 1
OPTION SELECTION EXAMPLE: X2DDLANFA224
SOLENOID DESIGNATION
F 740 Coil-Normally Open (with FDCB primary cartridge, Fully adjustable pressure compensated flow control valve with reverse flow check)
U 740 Coil-Normally Closed (with FDCB primary cartridge, Fully adjustable pressure compensated flow control valve with reverse flow check)
X No Solenoid Valve (with FDCB primary cartridge, Fully adjustable pressure compensated flow control valve with reverse flow check)
PRIMARY CARTRIDGE CONFIGURATION